| Specification | Details |
|---|---|
| Technology | 2.45GHz Cryomagwave, PGW, HIFEM |
| Microwave Frequency | 2450 MHz |
| Microwave Handpieces | 3 Aluminum Resonator Handpieces |
| Magnetic Stimulation Handpieces | 2 HIFEM Handpieces |
| Treatment Depths | 3 / 7 / 15 mm |
| Small Handpiece Output | 50–87 W |
| Medium Handpiece Output | 70–140 W |
| Large Handpiece Output | 70–160 W |
| Electromagnetic Intensity | 6.6 T |
| Pulse Width | 300 μs |
| Cooling System | Compressor Cooling |
| Cooling Temperature | 10–20°C |
| Display | 12.1-inch Touchscreen |
| Operating Modes | Preset & Custom Modes |
| Power Supply | 110V / 60Hz |
| Rated Power | 700 W |
| Machine Dimensions | 54 × 38 × 96 cm (21.3 × 15.0 × 37.8 in) |
| Net Weight | 58 kg (127.9 lb) |
| Package Dimensions | 67 × 66.5 × 112 cm (26.4 × 26.2 × 44.1 in) |
| Gross Weight | 86 kg (189.6 lb) |
Intelligent Touchscreen Control System
HIFEM Magnetic Stimulation Control
Custom Parameter Settings
Machine Structure & Connection Overview
Advanced Aluminum Resonator Handpiece Technology
Three Specialized Applicators: Small, medium, and large handpieces designed for precise facial treatments and broader body contouring applications.
Higher Maximum Output: The aluminum resonator version delivers up to 160W, compared with 120W in the standard copper-wire antenna version — approximately 33% higher maximum output power.
Professional Treatment Flexibility: Different applicator sizes and adjustable power settings allow practitioners to tailor treatments to different facial and body areas.
Dual HIFEM Magnetic Applicators
Equipped with two dedicated magnetic stimulation handpieces, the system delivers integrated HIFEM technology for professional muscle stimulation and body contouring treatments.
6.6T Electromagnetic Intensity | 300μs Pulse Width
Designed for professional treatment programs with adjustable stimulation intensity and customizable operating parameters.
Fat Reduction & Body Contouring: Cryomagwave microwave technology supports targeted body contouring treatments for areas such as the abdomen, waist, arms, and thighs.
Skin Firming & Facial Contouring: Specialized microwave applicators support facial firming, skin elasticity improvement, and contour refinement for the face, jawline, and neck.
HIFEM Muscle Stimulation: Dedicated magnetic stimulation applicators support muscle activation and body sculpting, complementing microwave contouring treatments.
What’s Included
– Main Unit × 1
– Microwave Treatment Handpieces × 3
– HIFEM Magnetic Stimulation Handpieces × 2
– Power Cable × 1
– Fixing Straps × 3
– Screwdriver × 1
– Connection Tubes and Installation Accessories
The system combines microwave-based contouring and HIFEM magnetic muscle stimulation in one professional platform. Clinics can integrate these technologies into their existing facial firming and body contouring services, expanding treatment options without investing in separate systems.
A professional consultation and contraindication screening should be completed before treatment. Contraindications include pregnancy, metal implants or artificial fillers in the treatment area, malignant tumors, certain cardiovascular conditions, epilepsy, severe hypertension, and severe diabetes. Practitioners should review each client’s health history before proceeding.
Yes. The system provides preset and custom HIFEM treatment modes. Practitioners can adjust stimulation intensity, frequency, rise time, duration, descent time, and interval time to configure treatment protocols for individual client needs.
Clinics should establish clear treatment goals during consultation, document baseline conditions, and monitor progress throughout the treatment plan. Results may vary depending on individual client characteristics, treatment areas, and selected protocols.
Routine maintenance includes inspecting power cables and connections, cleaning the equipment exterior with a suitable neutral cleaner when powered off, and cleaning treatment handpieces after each session. The cooling system and related components should also be monitored regularly.
The system provides diagnostic alerts for issues such as abnormal microwave handpiece water flow, low coolant levels, cooling temperature detection errors, compressor communication problems, and magnetic handpiece connection or temperature alerts. Practitioners can identify the issue using the diagnostic information and contact Gulgul technical support if assistance is required.
Yes.Rehyxa offers preferential pricing on replacement handpieces and spare parts for customers who purchase their equipment from us. Contact our team with your equipment model and required components to check availability and receive a personalized quotation.
Clients can generally resume their usual daily activities after treatment. Mild soreness or swelling may occur in some cases. We recommend avoiding saunas, hot springs, extreme temperature exposure, and strenuous exercise for 24 hours following treatment.
Traditional cryolipolysis primarily uses controlled cooling for localized fat reduction. Cryomagwave combines 2.45GHz microwave technology, integrated cooling, and HIFEM magnetic muscle stimulation in one professional platform, offering clinics a broader range of facial and body contouring treatment options.