Three Treatment Modes with Four Dedicated Handpieces
01. RF Microneedling
Uses the microneedling handpiece for controlled RF microneedling applications.
02. Non-Invasive RF
Uses the corresponding non-invasive treatment setup for contact-based RF applications without microneedling.
03. Thermal Care
Uses two dedicated RF handpieces for controlled thermal treatment applications.
Adjustable RF Microneedling for Facial & Body Treatments
The microneedle mode provides adjustable treatment parameters for different treatment areas. Facial treatments support needle depths from 0.5–2.5 mm, while body settings can be adjusted from 0.5–7 mm. Working time and energy can also be configured according to the treatment protocol.
- Working Time:1–99 min
- Facial Energy:0–200 W
- Body Energy:0–300 W
- Facial Needle Depth:0.5–2.5 mm
- Body Needle Depth:0.5–7 mm
- Single / Continuous Mode
- Consumable Usage Count
- 5 Custom Parameter Memories
Multiple Microneedling Consumable Options
The system supports multiple microneedling consumable configurations, giving professionals greater flexibility when planning treatments for different areas.
Nano Pins
For the corresponding microcrystalline treatment application.
12 Pins
For smaller treatment areas.
24 Pins
For facial and neck applications.
40 Pins
For larger treatment areas.
Non-Invasive Treatment
The non-invasive treatment interface provides adjustable working time and energy settings, allowing professionals to configure treatment parameters through the touchscreen.
The interface also provides treatment mode selection, consumable usage tracking and five customizable parameter memory settings.
- Working Time:1–99 min
- Energy:0–300 W
- Needle Depth setting:0.5–2.5 mm
- Single / Continuous Mode
- Consumable Count
- 5 custom parameter memories
Radiofrequency Thermal Care
The dedicated thermal-care interface allows professionals to adjust treatment time and RF energy for controlled thermal treatment.
Two handle parameter interfaces are provided, with adjustable energy output from 0–100 W.
- Handlebar parameter settings
- Small handle parameter settings
- Working time:1–99 min
- Energy:0–100 W
- 5 custom parameter memories
- Start / Stop
Fixed & Multi-Level Treatment Modes for Flexible Treatment Control
The system provides two operating modes for different treatment approaches: Fixed Mode and Explosive Mode. Both modes combine motorized microcrystal penetration with RF energy delivery, while using different movement and depth sequences.
Fixed Mode — Controlled Single-Point Treatment
In Fixed Mode, the microcrystals move into the skin to a preset depth before RF energy is delivered.
- Motorized microcrystals penetrate approximately 2.5 mm into the skin.
- RF energy is then delivered to the treatment area.
- Heat can continue to transfer approximately 1 mm upward and downward around the treatment point.
- The microcrystals then retract and exit the skin.
- The diagram illustrates treatment depths of approximately 1.5 mm, 2.5 mm, and 3.5 mm.
Explosive Mode — Multi-Level Treatment
Explosive Mode uses a deeper, multi-stage movement sequence to deliver RF energy at different levels.
- The motorized microcrystals initially penetrate up to 7 mm.
- RF energy is delivered with heat transfer across approximately 0.5–8 mm.
- The microcrystals then retract to 5 mm, followed by another RF energy output with heat transfer across approximately 0.5–6 mm.
- They continue retracting to 3 mm, followed by another RF energy output with heat transfer across approximately 0.5–4 mm.
- The microcrystals then fully retract and exit the skin.
Targeted Skin Concerns & Visible Changes
Enlarged Pores
Helps improve the appearance of enlarged pores and supports a smoother-looking skin texture.
Acne Scars
Designed for customized professional care targeting the appearance of acne scars and uneven skin texture.
Sagging Skin
Adjustable RF microneedle treatment supports professional protocols targeting skin laxity and sagging, particularly around the middle and lower face.
Neck Wrinkles
Supports customized professional treatment plans targeting visible neck wrinkles.
Fine Lines & Wrinkles
Supports professional anti-aging treatments targeting visible fine lines and wrinkles.
Rough Skin Texture
Microneedle treatment helps create microchannels in the skin and supports the skin’s natural repair process for rough and uneven-looking texture.
Technical Specifications
| Specification | Details |
|---|---|
| Product Type | Professional RF Skin Treatment System |
| Functions | Microneedle / Non-Invasive / Radiofrequency |
| Controller Frequency | 2 MHz |
| Screen | 12.1-inch Capacitive Touchscreen |
| Resolution | 1280 × 800 |
| Input Power | 50 W |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Instrument Size | 440 × 440 × 1200 mm |
| Microneedle Handles | 2 |
| Radio Frequency Handles | 2 |
| Microneedle Consumables | 4 |
| Non-Invasive Consumables | 3, optional |
| Microneedle Max Output | 35 W |
| RF Handle Max Output | 35 W |
| Fuse | 250 V / 10 A |
What’s Included
- Host × 1
- Microneedle Handles × 2
- Radio Frequency Handles × 2
- Microneedle Handle Holders × 2
- Radio Frequency Handle Holders × 2
- Pedals × 2
- Microneedling Consumables × 4
- Non-Invasive Consumables × 3 — Optional
- Power Cord × 1
- Specification / User Manual × 1
Safety & Professional Use
Only trained and qualified professionals should operate or maintain the equipment.
Before treatment, practitioners should review the patient’s medical history, explain the treatment and potential risks, remove jewelry and metal accessories, and confirm that the treatment area is appropriate. 慕菲斯使用说明书-英(2)
The manual also lists conditions and situations requiring exclusion or caution, including implanted electronic devices, certain implants, pregnancy or breastfeeding, active skin conditions, certain systemic conditions, coagulation disorders, recent procedures and certain previous device treatments.
FAQ
How many treatment functions does the system provide?
The system provides three treatment interfaces: Microneedle, Non-Invasive and Radiofrequency.
How many handpieces are included?
The system includes two microneedle handles and two radio frequency handles.
What is the microneedle depth range?
For facial settings, the adjustable needle insertion depth is 0.5–2.5 mm. For body settings, it is 0.5–7 mm.
What is the RF frequency?
The controller frequency is 2 MHz.
Can treatment parameters be saved?
Yes. Up to five customized parameter settings can be saved in the treatment interface.
Are the microneedling consumables reusable?
No. The manual states that the treatment needle must be used only once and cannot be re-sterilized.