How 448kHz RF Technology Works
Controlled Radiofrequency Energy for Professional Beauty Treatments
The TECAR Therapy Machine uses 448kHz radiofrequency technology to deliver high-frequency electrical energy through the treatment applicator and return electrode. As the energy passes through the targeted tissue, electrical resistance generates heat within the treatment area.
With adjustable energy settings, beauty professionals can customize treatments according to the selected body area, client comfort, and individual treatment needs.
448kHz Radiofrequency
High-frequency electrical energy designed for professional aesthetic applications.
Internal Heat Generation
Radiofrequency energy interacts with tissue to generate heat within the treatment area.
Adjustable Energy Control
Flexible energy settings allow professionals to tailor each session to different treatment needs.
Dual CAP & RES Radiofrequency Modes
Two Operating Modes for Personalized Face & Body Beauty Treatments
CAP – Capacitive Mode
CAP mode uses a capacitive electrode to deliver radiofrequency energy into the treatment area. The interaction between RF energy and tissue generates internal heat, making it suitable for professional beauty treatments focused on skin appearance and comfort.
Beauty Benefits
-
Supports skin firmness and elasticity
-
Helps improve the appearance of fine lines and wrinkles
-
Supports a smoother, more refreshed skin appearance
-
Provides gentle, adjustable warming for aesthetic treatments
Treatment Areas
Face · Neck · Arms · Abdomen
RES – Resistive Mode
RES mode uses a resistive electrode to deliver high-frequency energy through the treatment area. As the energy interacts with tissue resistance, it generates internal heat and provides an additional approach for professional body beauty treatments.
Beauty Benefits
-
Provides internal warming for body beauty treatments
-
Supports body contouring and firming routines
-
Helps improve the appearance of uneven skin texture
-
Expands treatment options for different body areas
Treatment Areas
Abdomen · Waist · Thighs · Buttocks · Back
Designed for Professional Beauty Studios
A Versatile Addition to Your Aesthetic Services
Beauty Salons
Expand professional face and body beauty services with adjustable RF treatment options.
Aesthetic Studios
Integrate CAP and RES radiofrequency applications into customized aesthetic service menus.
Spas & Wellness Centers
Offer operator-controlled RF beauty sessions within a professionally managed treatment environment.
Professional Face & Body Treatment Techniques
Versatile Application Techniques for Different Beauty Treatment Areas
The TECAR Therapy Machine supports a variety of professional facial and body beauty applications. Different applicator movements can be selected according to the treatment area, helping beauty professionals provide personalized treatments.
Facial Beauty Treatments
-
Jawline & Chin: Upward and outward movements along the jawline and chin.
-
Cheeks: Gentle lifting movements from the center of the face toward the outer cheeks.
-
Around the Mouth: Controlled movements around the mouth area.
-
Forehead: Upward movements across the forehead.
-
Under-Eye Area: Gentle movements around the orbital area, where permitted by the device instructions.
Body Beauty Treatments
-
Abdomen & Waist: Circular, upward, and directional movements across the abdominal area.
-
Thighs: Upward movements from the lower thighs toward the upper legs.
-
Buttocks: Upward and inward movements following the natural contours of the area.
-
Chest Area: Upward movements around the upper chest area, subject to the device’s approved operating instructions.
Why Choose This TECAR Therapy Machine?
Versatile Technology for Professional Beauty Businesses
Dual CAP & RES Modes
Switch between capacitive and resistive radiofrequency applications to support a wider range of professional facial and body beauty treatments.
Versatile Facial & Body Applications
Expand your service offerings with treatment options for selected facial and body areas, according to the applicator and approved treatment protocols.
Multiple Treatment Heads
Interchangeable treatment heads provide flexibility for different application areas and professional treatment routines.
Intuitive LCD Control
The 7-inch LCD screen makes it convenient for practitioners to view and adjust treatment settings during operation.
448kHz Radiofrequency Technology
Built around 448kHz RF technology, this system offers a dedicated radiofrequency platform for professional aesthetic applications.
A Practical Addition to Your Business
Designed for beauty salons, aesthetic studios, and spas looking to expand their professional facial and body treatment services with one versatile system.
Product Showcase
- 7-inch LCD screen
-
RES interface
-
CAP interface
-
Negative plate interface
-
Power switch
-
Power cord interface
What’s Included
- Main Unit × 1
- Treatment Handpieces × 2
- Treatment Head Set × 1 Set
- Negative Plate × 1
- Power Cord × 1
How to Operate the TECAR Therapy Machine
Step 1: Power On
Turn on the main switch, tap the screen power button, and enter the handpiece interface.
Step 2: Prepare Accessories
Position the negative plate as instructed and securely attach the appropriate treatment head. Pause the handpiece before changing heads.
Step 3: Set Parameters
Select the operating mode and treatment settings according to the user manual.
-
Facial: Start at energy level 15; 10–20 minutes.
-
Body CAP: Start at energy level 30.
-
Body RES: Start at energy level 40–60. Reassess after 3–5 minutes and adjust as appropriate.
Use compatible conductive cream where required. Keep ceramic heads away from corrosive products.
Step 4: Perform Treatment
Use controlled point-by-point or gliding movements along the recommended treatment pathways. If heat feels excessive, keep the applicator moving as appropriate and reduce the energy. Stop if discomfort persists.
Product Specifications
|
Specification |
Details |
|---|---|
|
Model |
ITB-2000 |
|
Rated Voltage |
AC 110–220V |
|
Rated Power |
350W |
|
RF Frequency |
448kHz |
|
Net Weight |
10kg (22.05 lb) |
|
Gross Weight |
20kg (44.09 lb) |
|
Product Dimensions (L × W × H) |
45 × 47.5 × 19cm (17.72 × 18.70 × 7.48 in) |
|
Package Dimensions (Flight Case) |
60 × 51 × 42cm (23.62 × 20.08 × 16.54 in) |
|
Display |
7-inch LCD Screen |
|
Operating Modes |
CAP & RES |
Safety & Usage Precautions
Important Guidelines for Safe and Professional Operation
The TECAR Therapy Machine is intended for professional aesthetic use. Operators should review the user manual, assess client suitability, and follow appropriate safety procedures before each session.
Contraindications
Do not use the device on individuals with:
-
Heart Conditions or Pacemakers: Particularly those with implanted cardiac electronic devices.
-
Uncontrolled High Blood Pressure: Or significant unexplained blood pressure fluctuations.
-
Pregnancy: Avoid use during pregnancy.
-
Epilepsy or Active Seizure Disorders.
-
Cancer or Active Tumors.
-
Impaired Skin Sensation: Including areas where the client cannot reliably detect heat or discomfort.
-
Active Medical Conditions: Clients experiencing an acute illness or other significant medical concerns should not undergo treatment without appropriate medical clearance.
During Treatment
-
Avoid application to the head, throat, and precordial (heart) region.
-
Use only on treatment areas permitted by the manufacturer.
-
Ensure proper electrode contact and adjust energy according to client comfort and the operating instructions.
-
Do not perform treatments immediately after meals or alcohol consumption.
-
Stop treatment immediately if excessive heat, pain, or unusual discomfort occurs.
After Treatment
-
Follow the manufacturer’s aftercare instructions, including avoiding immediate cold showers.
-
Allow the client to rest and recover comfortably after the session.
-
Encourage normal hydration according to individual needs.
Important: This device is intended for aesthetic applications and is not a substitute for medical diagnosis or treatment. Professional operators must follow the manufacturer’s complete instructions and contraindications.
FAQ
This professional TECAR Therapy Machine is designed for facial and body beauty treatments. Its dual CAP and RES radiofrequency modes offer versatile application options for beauty salons, aesthetic studios, and spas.
CAP mode uses capacitive radiofrequency application, while RES mode uses resistive radiofrequency application. Both generate heat through the interaction of RF energy with tissue, providing different approaches for professional beauty treatments.
Depending on the applicator and approved treatment protocol, the machine may be used on selected areas such as the face, neck, arms, abdomen, waist, thighs, and back. Always follow the manufacturer’s instructions for permitted treatment areas.
Yes. The machine features a 7-inch LCD screen for convenient operation and parameter adjustment. Treatment settings should be selected according to the manufacturer’s instructions and the client’s individual needs.
The standard package includes one main unit, two treatment handpieces, one set of treatment heads, one negative plate, and one power cord.
Yes. It is designed for professional beauty environments, including beauty salons, aesthetic studios, and spas looking to incorporate facial and body radiofrequency treatments into their service offerings.