Technical Specifications
| Specification | Details |
|---|---|
| Laser Wavelength | 10,600 nm |
| Rated Output Power | 40 W |
| Energy Adjustment Range | 1–40 W |
| Optical Beam Quality | TEM00 |
| Maximum Scan Area | 20 × 20 mm |
| Scanning Speed | More than 10 m/s |
| Spot Size | 0.02–0.05 mm² |
| Output Modes | Continuous, Single Pulse, Interval Pulse, Super Pulse |
| Scanning Patterns | Circle, Triangle, Square, Rectangle, Hexagon, Ellipse, Line |
| Scanning Modes | Random, Normal, Midsplit |
| Cooling System | Closed-Loop Internal Water Cooling |
| Guide Arm | Seven-Joint Articulated Arm |
| Voltage | 110V / 220V |
| Package Dimensions | 52 × 42 × 120 cm (20.5 × 16.5 × 47.2 in) |
| Gross Weight | 50 kg (110.2 lb) |
CO₂ Fractional Laser for Acne Scar Improvement
Fractional CO₂ Laser for Acne Scar Improvement
The fractional CO₂ laser delivers controlled laser energy in a fractional pattern, creating microscopic treatment zones within the skin while leaving surrounding tissue intact. Triggers the skin’s natural repair response and supports collagen remodeling.
Designed for professional skin resurfacing targeting atrophic acne scars and related skin concerns.
Pigmentation and Skin Tone Improvement
The fractional CO₂ laser can be used in selected professional skin resurfacing procedures targeting the appearance of freckles, sun spots, age spots, and uneven skin tone. It helps address visible skin irregularities associated with sun exposure, skin aging, and changes in skin texture.
By creating controlled microthermal treatment zones, the technology supports the skin’s natural renewal process and collagen remodeling. This process helps improve the appearance of uneven pigmentation, rough skin texture, and visible surface irregularities.
Treatment Modes
Fractional CO₂ Laser Probe
Designed for fractional skin resurfacing applications, including acne scar appearance, uneven skin texture so on.
Standard CO₂ Laser Probe
Designed for pulse-based tissue ablation and cutting applications within the device’s authorized scope of use.
Dedicated Intimate-Area Treatment
Specialized treatment probes designed for professional CO₂ laser treatments in women’s intimate areas.
Scanning Patterns
Flexible Scanning Patterns for Precision Treatment
The CO₂ laser system features seven selectable scanning patterns, including circles, triangles, squares, rectangles, hexagons, ellipses, and editable rectangles. These geometric patterns allow practitioners to define different treatment areas according to the size, shape, and requirements of each procedure.
The scanning dimensions can be adjusted to provide greater flexibility in controlling the laser coverage area. Practitioners. Combined with adjustable energy settings, dwell time, and point spacing.
Scanning Modes
Different scanning modes allow flexible treatment strategies to meet various clinical needs.
Scans point by point in sequence
The laser scans the treatment area point by point in a sequential order, row by row.
Scans from the center to both sides
The laser starts from the center of the treatment area and scans outward to both sides.
Scans the treatment area in a random sequence
The laser scans the treatment area in a random sequence without following a fixed pattern.
Output Modes
Different output modes provide flexible energy delivery to meet various treatment requirements.
Single Pulse
Delivers a single laser pulse each time it is triggered.
Continuous
Delivers continuous laser output with a steady energy flow.
Pulse
Delivers repeated laser pulses with adjustable pulse width and interval.
Operation video
Before & After Results
Individual results may vary depending on skin condition, treatment parameters, and professional assessment.
Machine Components
Package Include
- CO2 Scanning Machine Body
- Seven-Joint Articulated Arm and Treatment Head
- Key
- Funnel
- Foot Switch
- Power Cord
- Fractional CO2 Laser Probe
- Normal CO2 Laser Probe
- Dedicated Intimate-Area Treatment 1
- Dedicated Intimate-Area Treatment2
- Dedicated Intimate-Area Treatment 3
3-Year Warranty & Support
-
3-Year Warranty: Warranty coverage begins upon confirmed delivery.
- Replacement Parts: Spare parts and accessories are available upon request.
Shipping & Delivery
-
Sea Freight Only: All international orders are shipped via sea freight.
-
Secure Packaging: Carefully packaged to help protect the equipment from damage during transportation.
FAQ
Yes. The system includes an emergency stop switch designed to cut off the equipment’s power supply in abnormal situations.
Yes. The manual describes a preset function that allows up to five parameter configurations to be saved for later selection. Presets should be configured and used by trained operators for appropriate procedures.
The system uses a closed-loop water cooling system. Purified or distilled water should be replaced monthly. Routine maintenance also includes inspecting the seven-joint light guide arm, treatment head, cooling system, foot switch, and safety controls.
Operators must receive appropriate laser safety training and use wavelength-specific protective eyewear. The treatment area should have controlled access and laser warning signs. Reflective objects and flammable materials must be kept away from the laser operating area. Appropriate laser plume evacuation should also be provided.
Before operation, check the power connection, foot switch, cooling water level, guide arm installation, and treatment head condition. Ensure the equipment is clean and all connections are secure before starting the system.